Micro tillage machine safety operation technology
1. Before the operation, you must first read the instructions carefully, carry out the running-in maintenance strictly in accordance with the requirements of the instructions, and then must go through the operation and training.
2. Check whether the fastening fasteners of the machine are fastened before operation. Remember to tighten the bolts (including the traveling box section, the pressure box section, the engine support connection section, the engine muffler, the air filter, etc.).
3, will be placed in the horizontal position of the nose, body check whether to add enough oil, gear oil, can not be added, can not be added; check for oil leakage (oil, diesel, gear oil) phenomenon, can be used. At the same time remember that the fuel tank can not add gasoline, must add 0# diesel.
4. Add 1 ml of oil to the bottom of the air filter before use. The operation of the tiller is prohibited after drinking, the new machine is not allowed to work under heavy load, and tires should be changed in the field. In particular, operations on the slope should prevent the tiller from injuring others.
5. When starting up, be sure to confirm that there is no one before and after, and that it can be started after safety to avoid hurting people.
6, in the course of the work, the middle substitutions, talk with people, clear weeds when the knife holder, to turn off.
7. Do not walk on the concrete road or slate floor when installing the cultivator, and avoid collisions with hard objects such as large stones during operations to avoid damaging the blades. After discovering that the engine or walking box and the pressure box have abnormal noises, it is necessary to stop the inspection and remove the fault before working.
8. When the operator is less than 1 meter away from the side of the ridge in the operation, reverse operation is prohibited.
9. After the new engine works on 20 acres of land in normal operation, it must be replaced by heat engine oil and gear oil, otherwise the cold machine can not drain the residual oil in the engine; after 80~100 mu, replace it for the second time; after continuous operation for 3~5 days, After cleaning the air filter element, after 400~700 mu, check the pressure of oil pump and oil nozzle, check and adjust the valve clearance, replace the piston ring, valve and connecting rod if necessary.
10. After each season is completed, the soil, weeds, oil and other attachments on the tiller should be removed. At the same time, tighten the fastening fastener bolts, and find the film or other things to cover to prevent the sun and rain. Rusty.
Digital Radiography made affordable, Created to meet the needs of community to hospitals and private radiology practices, it enables the price-sensitive customers to join the drive to go digital.The versatile floor mounted radiography system enables you to go from film to CR to DR. Flooe-mounted easy for installation and operation.
The United-imaging is floor mounted system comprises a radiographic table with integral floor guide rail and a wallstabd. Requiring little room preparation, it is easy to install.
United-imaging according to the international advanced processing mode and standardlize design. the parts are made with precision CNC machine and moulding. Which adopt high degree of standardized, reasonable and compact structure. With reliable, durable and elegant appearance and advanced processing technology.




X-Ray Digital Machine,X-Ray Digital Machine In Medical,X-Rays Digital Medical Machine,Medical X-Ray Digital Imaging Machine
Shanghai Rocatti Biotechnology Co.,Ltd , https://www.shljdmedical.com