Brief description of maintenance procedures for rotary tablet press

Brief description of the maintenance procedures for rotary tablet presses (1) Check 1 Before each start-up, check the lubrication of the machine and refuel before driving.

2 Check the parts of the tablet press once a week to check whether the temperature rise of the bearing, the pressure wheel, the upper and lower rails are worn, and the defects should be repaired in time.

3 After the primary specification is completed, the remaining parts should be taken out and the residual powder of each part of the machine should be brushed. If the deactivation time is long, all the dies must be removed and the surface of the turret must be greased to prevent rust. And use a cloth hood to support.

(2) Lubrication and maintenance 1 The oil cup and the oil nozzle on the machine can be injected with grease or oil according to the type of oil cup. In the middle, the lubricant or lubricating oil can be adjusted or added according to the heating and running conditions of each component.

2 The felt in the upper pressure wheel cover absorbs the oil amount so as not to overflow, so as to lubricate the surface of the pressure wheel.

3 The surface of each track of the punch is lubricated with grease, so it should not be too much to prevent contamination of the powder.

4 The upper pressure wheel shaft can be directly lubricated with an exposed grease nipple. Spindle lubrication is added from the nozzle of the main body.

5 When the grease is added to the lower roller shaft, the table cover above the pressure roller can be removed and added from the oil nozzle at the end of the pressure roller shaft. If the direction is not correct, the nozzle can be rotated.

6 The worm gear box is lubricated with oil, and the oil level is not more than 1/3 of the lower part of the worm.

7 The die should be placed in the oil pool for use. Do not allow rust and bruises.

8 If the deactivation time is long, the smooth surface of the machine should be coated with anti-rust oil and covered with a plastic bag.

(3) The environment around the machine needs to be cleaned, and there should be no sand and fly dust.

(4) When the new machine is used, the lubricating oil in the worm gear box must be replaced for 3 months, and it should be determined later, but not more than 6 months.

(5) Designate a person to perform maintenance and maintenance on this unit.

(6) The failure of the maintenance 1 equipment cannot be ruled out after the operator checks it. Reports should be written and repaired by maintenance personnel.

2 When maintenance personnel perform maintenance, they should first read the equipment manual carefully and understand the basic conditions of the equipment before repairing.

3 When the maintenance personnel of the company are unable to repair, they shall be repaired by the equipment manufacturer and the equipment manufacturer.