How to use the pill machine correctly?

How to use the pill machine correctly?

(1) The whole machine is connected to the computer, and the host is connected to the compressed air line, and the adjustment pressure is 0.5 MPa. Turn on the main control switch and the illumination light on the side of the dripper on the dripper will light up. Indicates that the host power has been turned on; at the same time, the touch screen automatically enters the operation screen.

(2) Click "System Run" as needed.

(3) After the system enters the “Hand Function Status”, click “Parameter Setting” to set each parameter, then click “Confirm” button and press “Back” button to return to the operation screen.

(4) Click the “heat” button and the “switch” button of the heating oil pump, and the system enters the “preheating state” (this process will take about 1~2 hours). When the set temperature is reached, the system heating state will be automatically turned off or the hand function will be turned off to stop heating.

(5) Click on the "Refrigeration" switch. The system enters a cooling state and the compressor and fan start working (this process takes about 1-2 hours). After reaching the set temperature, turn off the chiller.

The “cooling” and “heating” processes can be synchronized, which reduces the waiting time for preparation.

(6) Click the “Magnetic Pump” switch to circulate the coolant. At the same time, pull the cylinder on the left side of the drip tank to lift the mold valve to raise the cooling column.

(7) Click the “nozzle heating” switch to bring the upper end of the cooling column to the set temperature.

(8) Drop: Click the "Auto" button in the menu. The automatic travel process is as follows: When the cooling and heating temperatures reach their set requirements, the system automatically starts stirring. When the set mixing time is reached, the system automatically opens the “feeding tube valve” dosing. After the drip tank is full, the "feeding tube valve" is automatically closed. At the same time, manually open the "Dripper" switch to start the drip, and automatically turn on the "Conveyor" switch, and the device will start running. When the liquid level drops to the lower limit level of the “drip tank”, the system again opens the “feeding tube valve” to add the medicine, and then automatically drops. When the dosing time has expired and the liquid level of the liquid does not reach the level on the “drip tank”, the alarm “Material has been used up, please turn to manual” appears on the touch screen. At this time, press the “Manual” button. The system is changed to the "automatic" state to the "manual" state, and the automatic travel process ends.

(9) Cleaning: When the liquid droplets are finished, no more dripping, or when another chemical solution needs to be replaced, it is necessary to clean the dripping system such as the “conduit tank” and the pipeline. The specific steps for cleaning are as follows:

1) Close the system program; 1 drip switch; 2 cooling oil pump; 3 refrigeration system; 4 lower the cooling column; 5 put the water tray on the lower part of the drip tank; 6 close the valve at the vacuum.

2) Add water: Inject a proper amount of hot water above 90 °C from the feeding port or the water inlet into the “conduit tank”.

3) Cleaning: Remove the dripper and inner shunt, replace the single-hole dripper, and connect the water conduit from the outlet of the dripper to the waste water tank. Then, open the air compressor, click to open the "feeding pipe valve" to inject hot water into the "drip tank", open the "dripper" switch, the waste water flows out under the pressure, and close the "dripper" switch. Repeat this dozens of times until the drip system is cleaned, and the water in the “conduit tank” is completely discharged, and the cleaned dripper is replaced.

(10) Turn off the system: After cleaning, turn off the air compressor; open the seasoning tank bleed valve to release compressed air; then turn off the touch screen, turn off the main power after the Zui.

YT-88

YT-88

YT-88

Shenzhen Sunshine Technology Co.,Ltd , https://www.shenzhenyatwin.com