Tilting sandwich pan safety use
1. The tilting type pot body is welded with flanges on both sides of the pot body, and is connected with the hollow shaft. The steam passes from the intake pipe into the hollow shaft and enters the interlayer. The packing box is filled with packing and the packing nut is pressed tightly to prevent leakage. gas.
Tilting sandwich pot picture display
2. The tilting device is a pair of worm gears with handwheels. When the handwheel rotates, the worm drives the worm wheel to rotate, and the tiltable sandwich pan body can be tilted 90 degrees and can be restored.
3. When the sandwich pot is used, the steam trap must be terminated at the outlet pipe.
4. For safe operation, a pressure gauge and a safety valve are installed on the intake pipe, and the working pressure is ≤0.2Mpm.
5. Always check the worm and worm gear of the tilting device for looseness, and lubricate the worm gear bearing every month.
Processing high-throughput samples, intelligent reuse for large-capacity publishing, work surface: 200cm, 8 sample injection needles, 12 temperature-controlled incubation positions, 12 room temperature incubation positions, 32 plate storage positions, Sunrise microplate reader, HydroFlex plate washer, up to 512 specimens, sequential loading of samples, reagents, microplates Parallel loading of up to 6 plates for fast dispensing.
The automatic enzyme immunoassay analyzer is based on the principle that the enzyme and the substrate can produce a color reaction, the absorption lines of different substances have different characteristics, and strictly abide by the Lambert-Beer law, quantitative and qualitative analysis of substances. instrument. The method of analyzing the content of various enzymes such as antigen or antibody generally mainly adopts colorimetric method. In practice, spectrophotometry is the basic working principle of an automatic enzyme immunoassay analyzer. The light emitted by the light source lamp becomes a beam of monochromatic light after passing through a filter or a monochromator. The monochromatic light beam passes through the sample to be tested in the microtiter plate, and part of the monochromatic light beam is absorbed by the sample and reaches the photodetector. The intensity of the light signal projected on it is converted into the magnitude of the electrical signal by the photodetector. This electrical signal is processed by pre-amplification, logarithmic amplification, analog-to-digital conversion, etc., and then sent to the microprocessor for data processing and calculation, and the test results are output by the display and printer. The microprocessor completes the movement in the X and Y directions of the mechanical drive through the control circuit.
The automatic enzyme immunoassay analyzer adds the sample to the microwells of the pre-coated antigen or antibody microtiter plate, washes after the reaction, removes the unseparated ligand, then adds the enzyme isolate, after incubation, washes again , remove the unseparated compound, and then add the enzyme substrate, after the reaction, the colored final product is formed, and the stop solution is added to stop the reaction. The absorbance of each microwell of the microtiter plate is read by the wavelength that has been set by the spectrophotometer. The concentration value of the analyte in the sample is calculated by the absorbance value of the sample and the standard curve, so that the quantitative result can be obtained, or the absorbance of the sample is compared with that of the standard product, so that the positive or negative qualitative result can be obtained.
ELISA analyzer,enzyme immunoassay workstation,automatic enzyme immunoassay analyzer,automatic enzyme immunoassay system
Jilin Sinoscience Technology Co. LTD , https://www.jilinsinoscience.com