Cheap Standard Hnt-1000 Infant Radiant Warmers with Price Baby Radiation Warming

Model NO.: HNT-1000
Medical Devices Reg./Record No.: Gxzz20153540574
Control Mode: Auto Mode
Temperature Control Range: 25~37°c.
Skin Temperature Sensor Measure Range: 20°c~42°c
Certificate: CE ISO
Temperature Rise Time: ≤45min
Input Power: ≤1000va
Skin Sensor Precision: ≤0.3°c
Bed Surface Temperature Uniformity: ≤1°c
Bed Tiltable: Continues Adjustable in ±10°
Warranty: 12 Months
Trademark: healicom
Transport Package: Carton
Specification: CE ISO
Origin: Jiangsu, China
HS Code: 9018909090
Model NO.: HNT-1000
Medical Devices Reg./Record No.: Gxzz20153540574
Control Mode: Auto Mode
Temperature Control Range: 25~37°c.
Skin Temperature Sensor Measure Range: 20°c~42°c
Certificate: CE ISO
Temperature Rise Time: ≤45min
Input Power: ≤1000va
Skin Sensor Precision: ≤0.3°c
Bed Surface Temperature Uniformity: ≤1°c
Bed Tiltable: Continues Adjustable in ±10°
Warranty: 12 Months
Trademark: healicom
Transport Package: Carton
Specification: CE ISO
Origin: Jiangsu, China
HS Code: 9018909090
STANDARD COMPOSITION
1. Servo Control Mode: air temperature
2. Instant Parameter Display: set temp, skin temp, heat power rate;
3. Audible/Visual Alarms: temp deviation, sensor failure, power failure, temp override;
4. Tilting Bed with Rotary Radiant Head
5. X-ray Cassette Tray under infant bed, examination light of high illuminance
6. Use anti-blast quartz infrared tube as radiant heating source.

TECHNICAL SPECIFICATION
Power Model HNT-1000-1E AC 110 / 120 V, 50Hz / 60Hz
Model HNT-1000-2E AC 220 / 240V, 50Hz / 60Hz
Input Power ≤1000VA
Temperature control range and relative specification Control mode Auto mode
Temperature control range 25°C~37°C.
Skin temperature sensor measure range 20°C~42°C
Deviation between sensor measure temperature and control temperature ≤0.5°C
Skin Sensor Precision ≤0.3°C
Bed surface temperature Uniformity ≤1°C
Temperature Rise Time ≤45min
Bed tiltable continues adjustable in ±10°
Alarm Sensor failure alarm Alarm with audible and visual when sensor open circuit, short circuit or disconnect, cut off power.
Over temperature alarm Alarm with audible and visual when displayed temperature was approach 38°C.
Deviation alarm After temperature equilibrium, alarm with audible and visual when displayed temperature was 1°C above or below control temperature, cut off power if above 1°C.
Power failure alarm Alarm with audible and visual when power failure
Environment Temperature
(It is a suggestion that please do not use outside of the allow environment.)
Operate temperature range 18°C~30°C
Store temperature range -20°C~+55°C
Environment Humidity Operate humidity range 30%RH~75%RH
Store humidity range ≤93%RH
Atmospheric pressure Transport and Store atmospheric pressure range 500hPa~1060hPa
Operate atmospheric pressure range 700hPa~1060hPa
Stream velocity Ambit environment stream velocity ≤0.3m/s

FAQ
1.What is time of delivery?
Since our products are produced according to each specific order, the delivery period will be 15days after confirmation of order. If it is small or sample order, please do check with us about whether we have ready goods in stock to make delivery as soon as possible.

2.What about quality assurance?
We offer one year warranty period beginning from the time of shipment for medical equipment, Per minor problems, we can provide free spare parts for replacements, Per serious problems, we can make replacement of free charge. But if the machine is damaged due to rough handling during the transportation, we are free of any responsibility, but we will still provide help to the buyer issue claims against the shipping company or insurance company, thus all the spare parts or expenses should be borne by buyer.

3.What about the price level?
We are confident that our prices are competitive compared with those at the same quality level, since we have stayed in this filed more than 20years. And we always adhere to the principle of provide top quality products with competitive prices.  We have already established our good fame in many countries, especially in Africa, Middle East, European, Asia and South American through year after year efforts.

4.Why we find some prices are very high compared with some other supplier, and from the picture or it's model number, all looks the same?
As China is still a developing country, there are only a few products with patent rights, and copy products l spread very fast in the market. Of course, the prices of those copy products with cheap material and less quality control are relatively cheaper .

5.What is payment terms?
T/T in advance,Western Union.

6.Which shipping company usually using?
MAERSK-LINE,PIL,COSCO,SAFMARINE,MARUBA,APL,CMA,CSAV,K-LINE,MSC,NYK,AND DHL,EMS,TNT,UPS FOR COURIER, buyer's option will be our priority.we will give suggestion according to the schedule and services. STANDARD COMPOSITION
1. Servo Control Mode: air temperature
2. Instant Parameter Display: set temp, skin temp, heat power rate;
3. Audible/Visual Alarms: temp deviation, sensor failure, power failure, temp override;
4. Tilting Bed with Rotary Radiant Head
5. X-ray Cassette Tray under infant bed, examination light of high illuminance
6. Use anti-blast quartz infrared tube as radiant heating source.

TECHNICAL SPECIFICATION
Power Model HNT-1000-1E AC 110 / 120 V, 50Hz / 60Hz
Model HNT-1000-2E AC 220 / 240V, 50Hz / 60Hz
Input Power ≤1000VA
Temperature control range and relative specification Control mode Auto mode
Temperature control range 25°C~37°C.
Skin temperature sensor measure range 20°C~42°C
Deviation between sensor measure temperature and control temperature ≤0.5°C
Skin Sensor Precision ≤0.3°C
Bed surface temperature Uniformity ≤1°C
Temperature Rise Time ≤45min
Bed tiltable continues adjustable in ±10°
Alarm Sensor failure alarm Alarm with audible and visual when sensor open circuit, short circuit or disconnect, cut off power.
Over temperature alarm Alarm with audible and visual when displayed temperature was approach 38°C.
Deviation alarm After temperature equilibrium, alarm with audible and visual when displayed temperature was 1°C above or below control temperature, cut off power if above 1°C.
Power failure alarm Alarm with audible and visual when power failure
Environment Temperature
(It is a suggestion that please do not use outside of the allow environment.)
Operate temperature range 18°C~30°C
Store temperature range -20°C~+55°C
Environment Humidity Operate humidity range 30%RH~75%RH
Store humidity range ≤93%RH
Atmospheric pressure Transport and Store atmospheric pressure range 500hPa~1060hPa
Operate atmospheric pressure range 700hPa~1060hPa
Stream velocity Ambit environment stream velocity ≤0.3m/s

FAQ
1.What is time of delivery?
Since our products are produced according to each specific order, the delivery period will be 15days after confirmation of order. If it is small or sample order, please do check with us about whether we have ready goods in stock to make delivery as soon as possible.

2.What about quality assurance?
We offer one year warranty period beginning from the time of shipment for medical equipment, Per minor problems, we can provide free spare parts for replacements, Per serious problems, we can make replacement of free charge. But if the machine is damaged due to rough handling during the transportation, we are free of any responsibility, but we will still provide help to the buyer issue claims against the shipping company or insurance company, thus all the spare parts or expenses should be borne by buyer.

3.What about the price level?
We are confident that our prices are competitive compared with those at the same quality level, since we have stayed in this filed more than 20years. And we always adhere to the principle of provide top quality products with competitive prices.  We have already established our good fame in many countries, especially in Africa, Middle East, European, Asia and South American through year after year efforts.

4.Why we find some prices are very high compared with some other supplier, and from the picture or it's model number, all looks the same?
As China is still a developing country, there are only a few products with patent rights, and copy products l spread very fast in the market. Of course, the prices of those copy products with cheap material and less quality control are relatively cheaper .

5.What is payment terms?
T/T in advance,Western Union.

6.Which shipping company usually using?
MAERSK-LINE,PIL,COSCO,SAFMARINE,MARUBA,APL,CMA,CSAV,K-LINE,MSC,NYK,AND DHL,EMS,TNT,UPS FOR COURIER, buyer's option will be our priority.we will give suggestion according to the schedule and services.

Manual Hydraulic Operating Table

The Operating Table use manual hydraulic control;Full set of hydraulic control system for hydraulic lock protection, low noise,high safty and reliability;This surgical table is divided into a plurality of movable segments;Operation table base with fixed or mobile, mobile and flexible, reliable fixation; The table is divided into several movable segments: head plate, back plate, seat plate, leg plate. Back plate is composed of shoulder and kidney (optional). All sections adopt transmissive X-ray material, the plate below is a cassette rail, which is used for cassette radiography.

ot table66

Manual Hydraulic Operation Table,Manual Hydraulic Ot Table,Manual Hydraulic Surgery Table,Manual Hydraulic Surgical Table

Shandong Lewin Medical Equipment Co., Ltd. , https://www.lewinmed.com