Tattoo Laser 1064nm 532nm Q-Switch ND: YAG Laser Tattoo Removal Machine

Model NO.: C5P
Wavelength: 1064 Nm / 532 Nm /1320nm
Power: 500W
Pulse Width: < 20ns
Spot Size: 1~5mm
Output: 200mj (1064nm), 100mj (532nm)
Repetition Rate: up to 10Hz
Control: 8 Inch, Touch Screen
Aiming Beam: Diode Laser 655nm (Red)
Trademark: SEA HEART
Transport Package: Aluminum Packing
Specification: 57x32x42cm, 15Kg
Origin: Beijing
HS Code: 8343709990

ND YAG Q-Switch Laser Tattoo Removal Machine 1064nm & 532nm Beauty Device
It can adjust the spot size from 1mm~5mm like articulated Arm handpiece, and exactly show the operator how big treatment area they do it. It is very convenient and make sure exactly and steady treatment.

 

Instruction :

As an upgrading version of mini Q-switch Nd:YAG laser tattoo removal, the C5P model can work for longer time with stable output, and more improvements in detail. A short pulse (shorter than 20ns) of laser beam emitted by the Q-switch Nd:YAG laser machine is selectively absorbed by the melanosome or the tattoo ink located in the epidermal & dermal skin layers. Pigmented lesions are all made of an over abundance of melanosomes in the skin. The laser energy causes the melanosome or tattoo ink to fragment into smaller pigment particles that are removed by your body's immune system.

The mini Q-switch Nd:YAG laser tattoo removal can be used for multiple applications. Equiped with the high efficiency laser generator and power supply, it is effcient for tattoo removing, speckle/spot removing, ota or freckle removing, etc. "Age spots" usually require only one to three treatments. Conditions, such as Nevus of Ota, freckles, and Other superficial skin discolorations may be removed in two to four treatments. In the case of tattoos, amateur tattoos usually require three to five treatments while professional tattoos may require six or more treatment sessions. Fading of the tattoo will continue in between treatment sessions as more ink is removed by your body. When more than one session is required, treatments should be spaced four to eight weeks apart to allow your body's natural immune system to remove the maximum amount of pigment or ink particles in between sessions.


Application

The system gem_adjusting Q switch can effectively curethe mixed pigments by pigment precipitation of extraneous source withpathological pigment change of endogenous source, inclusive of erroneous darkeyebrow-embroidery, lip-embroidery, lip-soak, eye line-embroidery, lipline,tattoo (inclusive of tattoo by extraneous wounds), pigment precipitation bysensitive source, freckle on female\'s face (male\'s), coffee spot, old agespot, black mole, and birthmark in black, blue, purple, brown, red and etc.Treatment course for different illness case as follows:

1. 1064nm Wavelength: Remove black and dark blue tattoo pigments, such as tattoos, eyebrows, dark color around the eyes, freckle, age spot etc.
2. 532nm Wavelength: Remove red and brown tattoos and red mark.
3. 1320nm wavelength: The 1320nm wavelength: Skin whitening and rejuvenation.  


 

Features

  • High energy (500W) laser output, so with least scar after treatment
  • Adjustable wavelength at 1064nm or 532nm, swiching on handpiece with one finger
  • Improved KPT filter for stable output in precise wavelength
  • Energy will not decline within 2 years
  • Permanently removal of pigment, safe treatment and low risk of scarring
  • High frequency up to 10 shots per second
  • Unnecessary to use the cream to numb the patients' skin
  • Quick recovery, low down time. After treatment, the slight edemais will disappear within a few days
  • High mobility - one of the smallest high energy laser in the world

 

Treatments Treatment course required ( cure times) Treatment course interval Remark (requirements in surgery)
eyebrow-embroidery(eyeliner grain) 1 -2 times 30-60 days Eyebrow blow, eyeball protection
Eyebrow-embroidery ( eyeliner embroidery) 1-3 times 45-60 days Eyebrow blow,  eyeball protection
Lip line (red dyed lip) 1-3 times 15-45 days Use 532nm filter
Tattoo(caused by extraneous wounds) 1-4 times 30-60 days Blood infiltration will be fine on wounds
Freckle, age spot 1-4 times 15-30 days Blood infiltration will be fine on wounds
Birthmark, nevus/mole 3-7 times 45-90 days Must  have  Blood infiltration .


Technical specification
Product Details
Type DKDP & KTP Nd: YAG Laser
Certification Medical CE / ISO13485 / RoHS / FDA / PSE
Model C5P
Wavelength 1064 nm / 532 nm /1320nm
Peak Power 500W
Pulse Width < 20ns
Spot Size 1~5mm
Cooling system Advanced air & water cooling system
Output 200mJ (1064nm), 100mJ (532nm)
Repetition Rate Up to 10Hz
Control 8 inch, Touch screen
Aiming beam Diode laser 655nm (Red)
Payment & Shipping
Minimum Order Quantity 1pcs
Packaging Details 57x32x42cm,15Kg
Delivery Time After confirm payment wihin 1-2 days
Payment Terms Paypal, Western Union, T/T
Supply Ability 50pcs/week



Tattoo Laser 1064nm 532nm Q-Switch ND: YAG Laser Tattoo Removal Machine
Tattoo Laser 1064nm 532nm Q-Switch ND: YAG Laser Tattoo Removal Machine



Contact Us
Kira  - Sales Representative 
Professional Sales Representative ,will help customs solve any problems if customs need.we like good and long cooperation.
© SEA HEART GROUP LIMTED. All Rights Reserved. WEBSITE: http://www.seaheartbj.com
 

Loose Tea Puerh

Pu'Er Tea,Chinese Pu'Er Tea,Tasty Pu'Er Tea

Prettyfly Technology Co., Ltd. , http://www.prettyflytea.com